1600 kVA Three Phase Pad Mounted Transformer

For industrial estates and facilities running heavy machinery, the FUTURE ELECTRIC 1600 kVA pad-mounted transformer supplies dependable three-phase power through a rugged, tamper-proof ground-level unit. Underground connections eliminate pole lines and reduce exposure to weather-related outages, while the robust cabinet protects live parts from contact. Available with aluminum or copper windings and built to recognized standards, it is engineered for continuous duty and minimal downtime.
  • Primary: 2.4-34.5 kV or Customized
  • Secondary: Customized
  • Winding: Cu / Al
  • Core : CRGO Silicon Steel / Amorphous Alloy
  • Application: Public Areas and Temporary Power Supply
  • Standards: IEEE/ANSI, UL / cUL/ CSA/ DOE /NEMA
Availability:

1600kVA Pad Mounted Transformer

The 1600 kVA pad mounted transformer is a three-phase, oil-immersed unit specified for continuous process and high density loads. Sitting on an outdoor pad with underground connections, it powers continuous process plants, steel and cement works, large data halls and refinery auxiliary systems. For plants that never shut down, the sealed design keeps the oil dry between maintenance windows.

Cooling is arranged as ONAN with KNAN fans available for peak periods, and the radiators are mounted clear of the doors. Bayonet and backup current limiting fuses protect the primary, Dyn11 or Yyn1 vector groups are standard, and the 1600 kVA pad mounted transformer is routine tested before dispatch. Gauges for oil temperature, level and pressure are fitted as standard.

Technical Specifications

Electrical & Standards

Rated Capacity

1600 kVA

Rated Primary Voltage

2.4/4.16/7.2/12.47/13.2/13.8/24.9/34.5 kV or Customized

Secondary Voltage

Customized

Frequency

50/60 Hz

Vector Group

Dyn11, Yyn1 or customized

HV Tap Changer

No-load / off-circuit ± 2×2.5%

Efficiency

DOE / NEMA TP-1

Temperature rise

55/65 °C

Impedance Voltage

4-6%

Cooling Method

ONAN/ KNAN

Operation

Step Down & Step Up

Standards/Certificate

IEEE/ANSI, UL / cUL/ CSA/ DOE /NEMA

Application

Residential communities, Commercial centers, Industrial plants, Airports and railway stations, Schools and hospitals, Data centers, Solar / wind farm step-up applications, Temporary power supply

Altitude

≤1,000 m, 1000–2000 m, 2000–3000 m, >3000 m

Material & Structure

Transformer Oil

Mineral Oil or FR3

Winding Material

Aluminum / Copper

Core Material

CRGO Silicon Steel / Amorphous Alloy

Color

Customized

Tank Material

Mild Steel / Stainless Steel

Sealing

Nitrogen / inert gas blanket

Feed type

Radial feed / Loop feed

HV termination

Dead-front / Live-front

Elbow connectors

Load-break / Dead-break

Enclosure

One-piece steel housing with separate HV / LV / transformer compartments

Enclosure rating

NEMA 3R, etc.

Mounting

On concrete pad

Cooling structure

Sealed oil tank with exposed radiators

Protection & Accessories

HV Protection

Bayonet fuse (Bay-o-net, dual-sensitive: temperature + current, field replaceable); backup current-limiting fuse (ELSP)

Switching

Oil-immersed load-break switch (2-position terminal / 4-position loop feed); vacuum interrupter optional

Pressure Protection

Pressure relief valve

Monitoring

Oil temperature gauge, oil level gauge, pressure / vacuum gauge (contacts optional)

Maintenance Ports

Drain valve, sampling valve, Schrader valve

Enclosure Accessories

Lifting lugs, hinged doors, flip-top cover, tamper-proof channel, ground strap / pads, nameplate, brass plug, 15 kV inserts with dust caps, CEA ground bracket

Optional

Lightning arresters, viewing windows, key interlocks, sudden pressure relay, electrostatic shielding, K-factor design, vacuum circuit breaker

1600kVA Pad Mounted Transformer Construction

box-type-transformer

1.CORE

It sits at the centre of the active part, stacked from cold-rolled grain-oriented silicon steel or amorphous alloy to form a closed magnetic circuit. Mitered 45° joints, core clamps and a single-point ground keep no-load loss, noise and circulating current low.

2.LV WINDING

The winding nearest the core limbs. Because the low-voltage side carries the highest current, it is normally wound as copper or aluminium foil, giving a uniform distribution of ampere-turns and a high short-circuit withstand capability.

3.HV WINDING

The outer winding, placed concentrically with the LV winding. It is built as a multilayer cylinder with oil ducts between layers, so the dielectric strength required by the primary voltage is achieved together with effective cooling of the conductor.

4.INSULATING OIL

The tank is filled with mineral oil or a natural ester such as FR3. The fluid insulates the windings, carries heat from the active part to the tank walls and radiators, and excludes moisture from the paper insulation to slow its ageing.

5.SEALED TANK & RADIATORS

A sealed mild steel or stainless steel tank with exposed radiators dissipates the heat of the loaded transformer by natural convection. The oil space is blanketed with nitrogen or an inert gas, so the fluid never meets outside air and remains maintenance free.

6.HV COMPARTMENT

The primary compartment is arranged for either radial or loop feed. Dead-front or live-front terminations are mated with load-break or dead-break elbow connectors, allowing the incoming cable to be isolated and the loop to be extended without exposing live parts.

7.LV COMPARTMENT

A separate low-voltage compartment brings the secondary leads out to underground service cables. Keeping the LV terminations in their own locked section means service work on the secondary side can be carried out without entering the primary compartment.

8.BAYONET FUSE & SWITCHING

Primary protection is provided by a Bay-o-net bayonet fuse that senses both temperature and current and is replaceable in the field, backed up by an ELSP current-limiting fuse. An oil-immersed load-break switch handles two-position or four-position loop operation.

9.TAMPER-PROOF ENCLOSURE

A one-piece steel housing divides the unit into separate HV, LV and transformer compartments, each with its own hinged door and tamper-proof channel. The enclosure is rated NEMA 3R, with lifting lugs, ground pads, a nameplate and viewing windows available.

10.PAD-MOUNTED BASE

The complete unit is mounted on a concrete pad, so no vault or fenced compound is needed and the transformer sits directly at the point of load. A pressure relief valve, drain valve, sampling valve and gauges are fitted for safe operation over its service life.

Transformer Testing & Quality Control

Every pad mounted transformer is tested before shipment against the applicable standards and customer requirements — from the first batch of raw material to the final routine test on the factory floor.

transformer-Raw-Material-Inspection
pad-mounted-transformer-test
01

Raw Material Inspection

Quality begins with the materials we bring in. Every batch of tank steel, core lamination, winding conductor and insulating fluid is inspected against approved specifications before production, with supplier qualification and traceability records maintained for each shipment.

02

In-process Inspection

Progress tests are conducted at key stages of the manufacturing process to verify that every 1600kVA three-phase pad mounted transformer meets design and quality requirements before final assembly.

03

Routine Tests

Before leaving the factory, each transformer undergoes routine testing — conducted in accordance with IEEE/ANSI, UL / cUL and CSA requirements for pad mounted distribution transformers — covering key parameters such as insulation resistance, winding DC resistance, voltage ratio and vector group, no-load loss and current, load loss and short-circuit impedance, applied and induced voltage withstand, and pressure tightness of the sealed tank.

Upon successful completion of all tests, the unit is shipped with a factory test report and a certificate of conformity, ensuring that every delivered product meets its rated performance and safety specifications.

Transformer Customization

1600kVA Pad Mounted Transformers are available with a range of configurable options to meet different electrical and environmental requirements. Customers can select the appropriate insulating fluid, voltage configuration, feed arrangement, protection devices and accessories according to their specific project conditions.

For projects with higher environmental and fire-safety requirements, a natural ester such as FR3 can be selected instead of conventional mineral oil. These fluids offer a higher fire point and good biodegradability, making them suitable where environmental protection and installation safety are important considerations.

The primary compartment can be configured for radial or loop feed, with dead-front or live-front terminations and load-break or dead-break elbow connectors. Protection options include bayonet fuses with current-limiting backup, oil-immersed load-break switches, lightning arresters, sudden pressure relays and oil temperature monitoring.

The enclosure can be supplied in mild steel or stainless steel with a customized finish, together with viewing windows, key interlocks, electrostatic shielding, K-factor designs for harmonic-rich loads, and vacuum circuit breakers where switching duty demands them.

box-type-transformer

Packaging & Shipping

pad-mounted-transformer-factory

We ensure every three-phase pad mounted transformer is safely packed, securely transported, and ready for installation.

Secure Packaging: Weather-resistant wooden crates or steel containers protect against moisture, vibration, and impact.

Complete Accessories: Fuses, elbow connectors, gauges and standard accessories are factory-installed and tested, while optional components are packed separately.

Reliable Transport: Road, rail, or sea shipping is arranged according to project requirements.

Complete Documentation: Test reports, certificates, manuals, and shipping documents are provided.

Installation Support: Siting on the concrete pad, cable termination and commissioning guidance is available for smooth project delivery.

FAQ From Customers

Can a pad mounted transformer step up as well as step down?

Yes. The unit can be configured to operate as a step-down transformer for a distribution load, or as a step-up transformer, for example on a renewable generation feeder.

Vector groups Dyn11 and Yyn1 are standard, with customized vector groups available on request.

Is the tank sealed?

Yes. The oil space is sealed under a nitrogen or inert gas blanket, so the fluid never comes into contact with outside air.

  • Prevents moisture ingress and oil oxidation
  • Removes the need for periodic oil top-up in normal service
  • Keeps the dielectric strength of the paper insulation stable over the service life

What switching options are available?

An oil-immersed load-break switch handles primary switching, and its configuration follows the feed arrangement of the network.

  • Two-position terminal arrangement for radial feed
  • Four-position loop feed arrangement for loop networks
  • Vacuum interrupter switching is available as an option

Rated Capacity

1600 kVA

Rated Primary Voltage

2.4/4.16/7.2/12.47/13.2/13.8/24.9/34.5 kV or Customized

Secondary Voltage

Customized

Frequency

50/60 Hz

Vector Group

Dyn11, Yyn1 or customized

HV Tap Changer

No-load / off-circuit  ± 2×2.5%

Efficiency

DOE / NEMA TP-1

Temperature rise

55/65 °C

Impedance Voltage

4-6%

Cooling Method

ONAN/ KNAN

Operation

Step Down & Step Up

Standards/Certificate

IEEE/ANSI, UL / cUL/ CSA/ DOE /NEMA

Application

Residential communities

Commercial centers

Industrial plants

Airports and railway stations

Schools and hospitals

Data centers

Solar / wind farm step-up applications

Temporary power supply

Altitude

≤1,000 m, 1000–2000 m, 2000–3000 m, >3000 m


Transformer Oil

Mineral Oil or FR3

Winding Material

Aluminum/Copper

Core Material

CRGO Silicon Steel / Amorphous Alloy

Color

Customized

Tank Material

Mild Steel / Stainless Steel

Sealing

Nitrogen / inert gas blanket

Feed type

Radial feed / Loop feed

HV termination

Dead-front / Live-front

Elbow connectors

Load-break / Dead-break

Enclosure

One-piece steel housing with separate HV / LV / transformer compartments

Enclosure rating

NEMA 3R, etc.

Mounting

On concrete pad

Cooling structure

Sealed oil tank with exposed radiators

HV Protection

Bayonet fuse (Bay-o-net, dual-sensitive: temperature + current, field replaceable); backup current-limiting fuse (ELSP)

Switching

Oil-immersed load-break switch (2-position terminal / 4-position loop feed); vacuum interrupter optional

Pressure Protection

Pressure relief valve

Monitoring

Oil temperature gauge, oil level gauge, pressure / vacuum gauge (contacts optional)

Maintenance Ports

Drain valve, sampling valve, Schrader valve

Enclosure Accessories

Lifting lugs, hinged doors, flip-top cover, tamper-proof channel, ground strap / pads, nameplate, brass plug, 15 kV inserts with dust caps, CEA ground bracket

Optional

Lightning arresters, viewing windows, key interlocks, sudden pressure relay, electrostatic shielding, K-factor design, vacuum circuit breaker

Previous: 
Next: 
Contact Us
Testing and Certification​​​​​​​
The Group's core businesses cover high-end manufacturing and industrial fields such as chemical products, transformers, and electrical equipment, with transformers and other electrical equipment being the Group's strategic leading industries.

PRODUCTS

QUICK LINKS

CONTACTS

 Tel: +86-18356911563
 Add: Shunhua Road Subdistrict, Lixia District, Jinan City, Shandong Province
 Opening Hours: 
work every day 9:00–18:00
Copyright © 2026 Shandong Future Electric Co., Ltd. All Rights Reserved.
Privacy Policy            Sitemap